Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
A/RH3-AN-BC-RRelative Humidity, RH Outputs: 0 |
3,187 |
|
![]() Datasheet |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CSI-RRelative Humidity, RH Outputs: 0 |
2,650 |
|
![]() Datasheet |
A/RHx-CSI | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-10KS-R2Relative Humidity, RH Outputs: 0 |
2,689 |
|
![]() Datasheet |
A/RHx-10KS | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-1K-3W-RRelative Humidity, RH Outputs: 0 |
4,498 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-50K-R2Relative Humidity, RH Outputs: 0 |
1,421 |
|
![]() Datasheet |
A/RHx-50K | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-R2S-A03-C5Relative Humidity, RH Outputs: 0 |
4,613 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-3K-R2LRelative Humidity, RH Outputs: 0 |
1,803 |
|
![]() Datasheet |
A/RHx-3K | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-1.8K-RRelative Humidity, RH Outputs: 0 |
2,174 |
|
![]() Datasheet |
A/RHx-1.8K | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CP-R-WRelative Humidity, RH Outputs: 0 |
4,463 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-100-3W-R2Relative Humidity, RH Outputs: 0 |
2,794 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-100-3W-RRelative Humidity, RH Outputs: 0 |
3,583 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-D-010Relative Humidity, RH Outputs: 0 |
4,532 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-D-BBRelative Humidity, RH Outputs: 0 |
2,911 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-R2Relative Humidity, RH Outputs: 0 |
3,958 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-RRelative Humidity, RH Outputs: 0 |
2,060 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH3-CP-R2SO-A11-G5Relative Humidity, RH Outputs: 0 |
1,427 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-AN-R2ORelative Humidity, RH Outputs: 0 |
3,955 |
|
![]() Datasheet |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH3-SP-05Relative Humidity, RH Outputs: 0 |
2,494 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Voltage | 0V ~ 5V | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-10KS-DRelative Humidity, RH Outputs: 0 |
3,606 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-AN-BC-DRelative Humidity, RH Outputs: 0 |
1,549 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |