Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
101188802NXT-400M-2003-02-FN |
4,841 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 12V | -15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188901NXT-400M-2004-01-FN |
3,085 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 15V | -12V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188902NXT-400M-2004-02-FN |
3,905 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 15V | -15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188701NXT-400M-2002-01-FN |
1,268 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 12V | - | - | - | - | 40 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188801NXT-400M-2003-01-FN |
1,628 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 12V | -12V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188601NXT-400M-2001-01-FN |
3,337 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 24V | - | - | - | - | 40 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188602NXT-400M-2001-02-FN |
2,803 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 28V | - | - | - | - | 40 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
101188702NXT-400M-2002-02-FN |
3,001 |
|
![]() Datasheet |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 15V | - | - | - | - | 40 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) | ||
![]() |
VB7G300MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 7V | - | - | - | - | - | 3 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB95GT20MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 95V | - | - | - | - | - | 200 mA | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 5.12" L x 3.71" W x 3.44" H (130.0mm x 94.2mm x 87.4mm) | ||
![]() |
VB15G300MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 15V | - | - | - | - | - | 3 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB25G170MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 25V | - | - | - | - | - | 1.7 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 5.12" L x 5.09" W x 3.44" H (130.0mm x 129.3mm x 87.4mm) | ||
![]() |
VB10G300MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 10V | - | - | - | - | - | 3 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB9G300MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 9V | - | - | - | - | - | 3 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB40GT100MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 40V | - | - | - | - | - | 1 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB8G300MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 8V | - | - | - | - | - | 3 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) | ||
![]() |
VB100GT20MAC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 100V | - | - | - | - | - | 200 mA | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 5.12" L x 3.71" W x 3.44" H (130.0mm x 94.2mm x 87.4mm) | ||
![]() |
VA90NT25MAC/DC CONVERTER |
500 |
|
![]() Datasheet |
A | Bulk | Active | Enclosed | 1 | 105 ~ 125 VAC | 90V | - | - | - | - | - | 250 mA | - | - | - | - | - | - | ITE (Commercial) | - | -20°C ~ 71°C | Adjustable Output, Remote Sense | Chassis Mount | 8.47" L x 3.84" W x 1.68" H (215.1mm x 97.5mm x 42.7mm) | ||
![]() |
MPU200-1048GAC/DC CONVERTER 48V 202W |
3,068 |
|
![]() Datasheet |
MPU200 | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 4.2 A | - | - | - | - | - | 202W | ITE (Commercial) | 2.6 kV | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.20" W x 1.50" H (203.2mm x 106.7mm x 38.1mm) | ||
![]() |
B3.3G400-230AC/DC CONVERTER |
1,000 |
|
![]() Datasheet |
B | Bulk | Active | Enclosed | 1 | 210 ~ 250 VAC | 3.3V | - | - | - | - | - | 4 A | - | - | - | - | - | - | ITE (Commercial) | - | 0°C ~ 71°C | Adjustable Output | Chassis Mount | 6.59" L x 5.12" W x 3.44" H (167.4mm x 130.0mm x 87.4mm) |